| Protection level (IP)   | According to IEC 60529, the protection level is IP54 | 
        
            | Drop test | 3 meters | 
        
            | Vibrationand Shock protecion | IEC 60068-2-6,2.5g, 10 to 200Hz, IEC 60068-2-27, 50g   | 
        
            | Laser safety | 11mEN 61325-1:2006 | 
        
            | Measuring distance | D:S=12:1 (measuring distance to target object) | 
        
            | Measuring condition | Vacuum medium | 
        
            | Spectral response | 8 to 14 Micron | 
        
            | Emissivity | 0.10 to 1.00 adjustable | 
        
            | Temperature coeffcient | ±0.1℃/℉ or ±0.1% of reading, whichever is larger | 
        
            | Optical resolution | 12:1 (when energy is 95% calculate ) | 
        
            | Display resolution |  0.1℃ / 0.2℉ | 
        
            | Repeatability (reading %) | Reading ±0.8% or 1.0℃/2, take the larger value | 
        
            | Auto power off time | approx. 6s | 
        
            | Sampling rate | ≤ 0.5s | 
        
            | Backlight display function | √ | 
        
            | Low battery indication | √ | 
        
            | Data hold function | √ | 
        
            | Max./Min./AVG./DIF. HOLD function | √ | 
        
            | High/Lowtemperature Alarm function | √ | 
        
            | Zero offset adjustment | √ | 
        
            | Unit Symbol display | √ | 
        
            | Max. display   | 3digits | 
        
            | Power supply | 6F22, 9V  (extra heavy battery) | 
        
            | Battery life | 10 hours when the laser and backlight are on. | 
        
            | Power consumption | ≤50mW | 
        
            | Meter weight | 177g (with battery) | 
        
            | Meter size | 95x43x155mm |